Heatmiser Programming Quick Guide

Programming Switching Times

  • Press PROG 
  • Type the User Security Code   
  • Press ENTER 
  • Press 2 for Data 
  • Type Start Time for Monday Period 1 
  • Press ENTER
  • Type End Time for Monday Period 1 
  • Press ENTER 
  • Repeat if further switching times are required - (Max 3 periods per day) 
  • Press RUN to return to the Normal Run Mode 

OVERRIDING THE HEATMISER

  • Press the OVERRIDE key
  • Enter the User Security Code (if required)
  • Press ENTER
  • Press 1 to enter the Override mode
  • Select either 1 or 2 to override the zone ON(1) or OFF(2)
  • Now enter the required Override period (e.g. 02 for 2 hours)
  • Press ENTER mode 

ALTERING TEMPERATURE SETTINGS 

  • Press PROG
  • Type the User Security Code, press enter
  • Select 1 for Temp
  • Type the required day temperature (eg. 22°C)
  • Press ENTER
  • Select 1 if you require Frost Protection or 2 if you do not
  • Enter, if required, the Frost setting (e.g. 08°C) •Enter, if required, the summer fan differential Setting. This is the number of °C above the DAY temperature that the summer fan relay will be activated.
  • Press ENTER
  • Press RUN to return to the Normal Run Mode 

TIME AND DATE

  • Press PROG
  • Type the User Security Code
  • Select 3 for System
  • Select 1 for System Time
  • Enter the current Time (e.g. 07.00)
  • Press ENTER
  • Enter the current date (e.g. 18-06-03)
  • Press ENTER
  • Enter the day of the week (e.g. 1=Mon, 7=Sun)
  • Press RUN twice to return to the Normal RUN mode

PROGRAMMING HOLIDAY PERIODS 

  • Press PROG
  • Type the User Security Code
  • Select 4 for Hols
  • Enter the holiday start date (e.g. 24-12-03)
  • Press ENTER •Enter the length of the holiday period (e.g. 10 days)
  • Repeat for further holidays
  • Press RUN twice to return to the Normal RUN mode 

NOTE:

  • 24 Hour Clock Notation should be used when programming the Heatmiser.
  • All Switching times should be actual occupancy times, no warm up period is needed.